8.7 Removing the single-fastener adapter
1. Remove the gas can. page 8
2. Remove the magazine. page 9
3. Remove the single-fastener adapter.
4. Fit the magazine. page 9
9 Remedying possible malfunctions
9.1 Remedying an incorrect piston position
Check the position of the RESET page 5 button.
Result
RESET button projects from the tool casing. Its white edge is visible.
To remedy the incorrect piston position, press the RESET button.
9.2 Removing foreign objects and nails from the area around the fastener guide
CAUTION
Risk of injury by flying parts! Triggering the tool (attempting to drive a fastener) when foreign objects are
present in the area around the fastener guide, or when a fastener is jammed in the fastener guide, may lead
to injury caused by flying objects or fragments.
Never attempt to remedy tool malfunctions by continuing to trigger the tool!
1. Remove the gas can. page 8
2. Unload the magazine. page 9
3. Remove the magazine. page 9
4. Remove all foreign objects and nails from the area around the fastener guide.
5. Fit the magazine. page 9
10 Care and maintenance
10.1 Caring for the fastening tool
Never operate the fastening tool if the cooling air slots are blocked.
Keep the grip areas free from oil and grease.
Clean the fastening tool regularly.
Do not use spray devices, pressure jet washers or running water for cleaning.
Do not use cleaning agents containing silicone.
Do not use sprays or similar lubricating and cleaning agents.
10.2 Cleaning the fastening tool
1. Remove the gas can. page 8
2. Unload the magazine. page 9
3. Use a dry brush to clean the cooling air slots, taking care to prevent dirt or foreign objects entering the
interior of the tool.
4. Use a damp cloth to clean the exterior of the tool.
11 Transport and storage
11.1 Maintenance
To help ensure safe and reliable operation, use only genuine Hilti spare parts and consumables. Spare
parts, consumables and accessories approved by Hilti for use with the product can be found at your
local Hilti Center or online at: www.hilti.group.
Check all external parts of the fastening tool for signs of damage at regular intervals and make sure that
all the controls function correctly.
Do not use the fastening tool if parts are damaged or if the controls do not function correctly.
Have a defective fastening tool repaired by Hilti Service.

Table of Contents

Other manuals for Hilti GX 3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hilti GX 3 and is the answer not in the manual?

Hilti GX 3 Specifications

General IconGeneral
BrandHilti
ModelGX 3
CategoryPower Tool
LanguageEnglish

Related product manuals