5.5 Calculation Formulas Specifications
161
Basic measurement parameter calculation formulas
5.5 Calculation Formulas Specifications
(1) Voltage basic calculation formulas
Item (RECTIFIER) Calculation formulas
RMS value (AC+DC)
Average value rectification
RMS value converted value
(AC+DC Umn)
Simple average value (DC)
AC component RMS values (AC)
Fundamental wave component RMS
values (FND)
U
1(i)
from harmonic calculation formula
Waveform peak value
Displays the maximum absolute value from the above with its polarity.
Total harmonic distortion
U
thd(i)
from harmonic calculation formula
Ripple rate
Crest factor
(i): Measurement channel; M: Number of samples between synchronized timing points; s: Sample point number
Voltage channel and sum value calculation formula
Wiring
1P2W 1P3W 3P3W 3P3W2M 3V3A 3P3W3M 3P4W
All channels Sum values
See note.
Basic calcula-
tion formula
U
(i)
Note:
Above applies to RMS values (AC+DC).
For average value rectification RMS values (AC+DC Umn), simple average values (DC), AC component RMS values
(AC), and fundamental wave component RMS values (FND), replace U
(i)
with U
mn(i)
, U
DC(i)
, U
AC(i)
, and U
1(i)
.
|u|
M
1
22
π
U
s)i(
1M
0s
)i(mn
−
∑
=
=
2
)i(DC
2
)i()i(AC
)U()U(U
−=
U
pk(i)
=
U
pk
+ (i) : u(i)
s
Maximum value from M values
U
pk
- (i) : u(i)
s
Minimum value from M values
100
|U|2
)|UU(|
U
)i(dc
)i(pk)i(pk
)i(rf
×
×
=
+ −
−