Display | LCD |
---|---|
Type | Power Meter |
Measurement Category | Category III |
Frequency Range | 0.5 Hz to 100 kHz |
Accuracy | ±0.1% of reading |
Power Accuracy | ±0.1% of reading |
Basic Accuracy | ±0.1% of reading |
Interfaces | USB |
Power Supply | 100 V to 240 V AC, 50/60 Hz |
Defines risk seriousness and hazard levels used in the manual.
Explains the meaning of various symbols found on the instrument.
Essential checks and procedures to perform before operating the instrument.
Guidelines for ensuring accurate measurements, including instrument warm-up and heat radiation.
Overview of the PW3335 Power Meter's capabilities and design.
Highlights the key functionalities and performance aspects of the PW3335 Power Meter.
Details the steps for installing the instrument and connecting measurement lines and power.
Explains how to properly connect voltage and current measurement lines, including wiring diagrams.
Provides instructions on connecting the instrument's power cord to an outlet.
Guides the user through the process of powering on the instrument and its self-test sequence.
Describes the procedure for zero-adjusting the instrument to ensure accurate measurements.
Explains how to safely activate power to the measurement lines after setup.
Details the proper procedure for turning off the instrument and disconnecting measurement lines.
Outlines essential checks before using the instrument to ensure proper operation and safety.
Covers various settings like current input, display parameters, ranges, and synchronization source.
Explains the instrument's integration function for measuring accumulated power or current over time.
Describes how to analyze and display harmonic components of voltage, current, and power.
Details how to connect and synchronize multiple PW3335 units for simultaneous measurements.
Explains how to control the instrument's functions using external devices via control terminals.
Covers generating voltage outputs proportional to measured parameters for data logging or analysis.
Guides on connecting and using optional current sensors for measuring high currents.
Explains additional functions like display hold, max/min values, key lock, and system reset.
Provides troubleshooting guidance for various indicator lamps and error displays.
Details the setup for connecting the instrument to a PC via LAN, RS-232C, or GP-IB interfaces.
Describes how to remotely operate the instrument using a PC web browser via the LAN connection.
Explains how to switch the instrument from remote control back to local panel operation.
Lists environmental operating conditions and safety standards compliance for the instrument.
Provides general technical specifications including input, power, dimensions, and interfaces.
Details the accuracy and performance specifications for various measurement parameters.
Describes the functional specifications of features like auto-range, averaging, hold, and synchronized control.
Lists the mathematical formulas used for calculating measurement parameters displayed by the instrument.
Offers solutions for common symptoms and issues encountered during instrument operation.
Explains the meaning of error codes and messages displayed by the instrument.
Provides detailed output specifications for level output parameters across different rectifiers.
Details the output specifications for high-speed level output parameters and their rated voltages.
Lists the output specifications for waveform output parameters, including instantaneous voltage and current.