Appendix 1 Detailed Specifications of Measurement Items (Display Items)
A
1
* During auto-range integration mode operation, this data is invalid (−: None).
Appendix
Appendix 1 Detailed Specifications of Measure-
ment Items (Display Items)
Measured value display (if using communications, measured value data) : Displayed −: Not displayed
Measurement items
Rectifier
Display range
AC+DC
AC+DC
Umn
DC AC FND
Voltage V
Up to ±152% of range. However,
zero-suppression when less
than ±0.5%
Current A
Up to ±152% of range. However,
zero-suppression when less
than ±0.5% or less than ±9 A.
Active power W ±0% to ±231.04% of range
Apparent power VA − 0% to 231.04% of range
Reactive power var − ±0% to ±231.04% of range
Power factor PF − ±0.0000 to ±1.0000
Phase angle ° −−−+180.00 to -180.00
Frequency
Voltage
Current
VHz
AHz
−−−−−0.1000 to 100.00 kHz
Current integration
Positive
Negative
Ah+
Ah-
−− −−
Display resolution
999999
Total Ah * * −−
Active power
integration
Positive
Negative
Total
Wh+
Wh-
Wh
−−
Display resolution
999999
Integration time TIME −−−−−00.00.00 to 10000.0
Waveform peak
value
Voltage
Current
Vpk
Apk
−−−−−Up to ±102% of peak range
Crest factor
Voltage
Current
CF V
CF A
−−−−−1.0000 to 612.00
Maximum current ratio MCR −−−−−1.0000 to 6.1200 M
Time average current T.AV A * * −−±0% to ±612% of range
Time average active power T.AV W −−±
0% to ±3745.4% of range
Ripple rate
Voltage
Current
RF V%
RF A%
−−−−−0.00% to 500.00%
Total harmonic
distortion
Voltage
Current
THD V%
THD A%
−−−−−0.00% to 500.00%