4.3 Canceling the Remote State (Activating the Local State)
133
During communications, REMOTE lamp is lit to indicate the remote control state.
Control keys are disabled, with the exception of .
If the remote state is activated while the instrument is displaying the Settings screen, it will automatically
switch to the normal display (Measurement screen).
SHIFT key (
) is disabled if the GP-IB controller has put the instrument into the local lock out state (LLO:
Local Lock Out).
In this case, run the
GTL command of the interface function, or reboot the instrument. Then it returns to the
local state.
Canceling the remote state
To switch the instrument from the remote state (with the REMOTE lamp lit up) to the local state (with panel
operation enabled), press .
The REMOTE lamp will turn off, and use of control keys will be enabled.
4.3 Canceling the Remote State
(Activating the Local State)
Press .
The REMOTE lamp will turn off, enabling use of
control keys.