EasyManua.ls Logo

Hioki PW8001-11 User Manual

Hioki PW8001-11
262 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
PW8001
Instruction Manual
POWER ANALYZER
EN
Dec. 2021 Edition 1
PW8001A961-00 21-12H
Read carefully before use.
Keep for future reference.
When using the instrument for
the rst time
Troubleshooting
Safety Information
p. 8 Maintenance and Service
p. 231
Measurement Procedure
p. 12 Troubleshooting
p. 233
Part Names and Functions
p. 15 Dialogs
p. 236
PW8001-01
PW8001-02
PW8001-03
PW8001-04
PW8001-05
PW8001-06
PW8001-11
PW8001-12
PW8001-13
PW8001-14
PW8001-15
PW8001-16
PW8001 POWER ANLYZER
Instruction Manual
www.hioki.com/
*600627740*
HIOKI PW8001A961-00

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Hioki PW8001-11 and is the answer not in the manual?

Hioki PW8001-11 Specifications

General IconGeneral
BrandHioki
ModelPW8001-11
CategoryMeasuring Instruments
LanguageEnglish

Summary

2 Preparing for Measurement

2.1 Inspecting the Instrument before Use

Crucial steps to ensure the instrument and its accessories are ready and safe for operation.

2.2 Connecting the Voltage Cords (Voltage Input)

Detailed instructions for correctly connecting voltage input cords to the instrument.

2.3 Connecting the Current Sensors (Current Input)

Procedures for connecting current sensors to the instrument's probe terminals.

2.4 Supplying Power to the Instrument

Steps for safely connecting and supplying power to the instrument.

2.5 Setting Wiring Mode and Configuring Current Sensor Settings

How to configure measurement wiring modes and current sensor parameters.

2.6 Simple Configuration (Quick Set)

Guide to using the Quick Set function for rapid measurement setup.

2.7 Zero Adjustment and Degaussing (Demagnetization)

Essential procedure for calibrating sensors and ensuring measurement accuracy.

2.8 Connecting Measurement Leads and Sensors to Lines to Be Measured

Practical guidance on connecting measurement leads and sensors to the circuit.

2.9 Checking Connections

Methods to verify correct sensor and cord connections for accurate measurements.

3 Displaying Power Numerically

3.1 Displaying Measured Values

How to view and configure the display of measured voltage, current, and power values.

3.2 Measuring Power

Detailed guide on measuring and displaying power values, ranges, and settings.

3.3 Integrating Current and Power

How to perform and control integration measurements for current and power.

3.4 Measuring Harmonic

Procedures for measuring and analyzing harmonic content of signals.

3.5 Measuring Efficiency and Loss

How to calculate and display efficiency and loss based on measured power values.

3.6 Motor Measurement (Motor Analysis-Equipped Model)

Specific functions and procedures for motor analysis using the equipped model.

4 Displaying Waveforms

4.3 Recording Waveforms

Detailed procedures for capturing and saving waveform data.

5 Various Functions

5.1 Time Control Function

How to use time control for auto-save and integration functions.

5.2 Average Function

How to apply averaging to measured values for stable display.

5.3 Hold Function

How to freeze and hold displayed values.

5.4 Peak Hold Function

How to capture and display peak values.

6 System Settings

7 Saving Data and Managing Files

11 Maintenance and Service

11.2 Troubleshooting

Common issues, causes, and solutions for troubleshooting the instrument.