Type | Power Meter |
---|---|
Model | PW3336-01 |
Display | LCD |
Measurement Category | Category III |
Power Range | 7.5000 to 12.000 kW |
Interface | USB |
Power Supply | AC 100 V to 240 V |
Safety guidelines for handling the instrument and measurement cables.
Safety guidelines for inputting signals and performing measurements, including limits.
Steps for installing the instrument and connecting wires/cords with safety checks.
Overview of configuring settings like wiring mode, input method, and display parameters.
Procedure for starting measurement, outputting data, and stopping the instrument.
Detailed steps for installing and connecting the instrument, including safety checks.
Instructions for connecting measurement lines, including polarity and external VT/CT usage.
Step-by-step guide for connecting cables to input terminals, including safety covers.
Details on different connection methods for measurement lines based on input range.
Checklist for peripheral devices and the instrument before starting measurement.
How to select the wiring mode (e.g., 1P2W, 1P3W) according to the measured line.
Procedure for selecting current input method: direct input or external sensor.
How to select display parameters, channels, and rectifiers for the instrument's display.
How to manually select voltage/current ranges and use auto-range operation.
How to set the synchronization source for calculations, selecting from voltage, current, or DC.
How to set the zero-cross filter and frequency measurement range for accurate synchronization.
How to set the timeout value for synchronization when input frequency is low.
How to set the number of averaging iterations to reduce display value variation.
How to set VT and CT ratios for measuring primary-side values when using external VT or CT.
Explains how the instrument performs integration for current and active power.
How to set an integration time for performing timer integration.
Important considerations and constraints when performing integration.
Methods for starting and stopping integration using instrument keys.
How to set the master (OUT) and slave (IN) roles for synchronized control.
Describes the external control terminals (START/STOP, RESET, HOLD) and their functions.
How to select output parameters, rectifiers, and channels for D/A output.
Safety and handling precautions before connecting current sensors.
Procedures for connecting TYPE1 and TYPE2 current sensors to the instrument.
How to set current sensor type, CT ratio, and range for external sensors.
How to activate and cancel display hold to freeze measured values.
How to switch between instantaneous, maximum, and minimum values.
How to enable and cancel the key lock function to prevent inadvertent operation.
How to initialize instrument settings to factory defaults via system reset.
Covers basic measurement specifications for voltage, current, active power, etc.