EasyManua.ls Logo

Hioki PW3336-01 - Power Channel and Sum Value Calculation Formulas

Hioki PW3336-01
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.5 Calculation Formulas Specifications
164
(3) Power calculation formulas
Item (RECTIFIER) Calculation formulas
Active power
(AC+DC, AC+DC Umn)
Active power simple average value
(DC)
Active power AC component (AC)
Fundamental wave active power
(FND)
P
1(i)
from harmonic calculation formula
Apparent power
(AC+DC, AC, AC+DC Umn)
Calculated values from the respective rectifiers are used for
U
(i)
and I
(i)
.
(For AC+DC Umn, the AC+DC value is used for current.)
Fundamental wave apparent power
(FND)
S
1(i)
from harmonic calculation formula
Reactive power
(AC+DC, AC, AC+DC Umn)
Calculated values from the respective rectifiers are used for P
(i)
and S
(i)
.
Fundamental wave reactive power
(FND)
Q
1(i)
from harmonic calculation formula
Power factor
(AC+DC, AC, AC+DC Umn)
Calculated values from the respective rectifiers are used for P
(i)
and S
(i)
.
Fundamental wave power factor
(FND)
λ
1(i)
value from harmonic calculation formula
Phase angle (AC)
Calculated values from the respective rectifiers are used for
λ
(i)
.
Fundamental wave voltage current
phase difference (FND)
ϕ
1(i)
from harmonic calculation formula
(i): Measurement channel; M: Number of samples between synchronized timing points; s: Number of sample points; si
(i)
:
Polarity symbol, acquired based on voltage waveform and current waveform lead and lag for each measurement channel
Symbol [None]: Current lags voltage (LAG).
Symbol [-]: Current leads voltage (LEAD).
Power channel and sum value calculation formulas
Wiring
Item
1P2W 1P3W 3P3W 3P3W2M 3V3A 3P3W3M 3P4W
All channels
Sum values
Active power
Basic calcula-
tion formula
P
(i)
=
×=
1M
0s
s)i(s)i()i(
)iu(
M
1
P
  
)i(DC)i(DC)i(DC
IUP ×=
)i(DC)i()i(AC
PPP =
)i()i()i(
IUS ×=
2
)i(
2
)i()i()i(
PSsiQ =
)i(
)i(
)i()i(
S
P
siλ =
When P
AC(i)
0
)i(
1
)i()i(
λcossiφ
=
(0° to ±90°)
)i(
1
)i()i(
λcos180siφ =
When P
AC(i)
< 0
90° to ±180°)
)2()1(sum
PPP +=
)3()2()1(su m
PPPP ++=

Table of Contents