Appendix 2 Detailed Specifications of Output
A
2
* During auto-range integration mode operation, the display will indicate Lo. (0 V output).
Appendix 2 Detailed Specifications of Output
Appendix 2.1 Detailed Specifications of Level Output
: Installed − : Not installed Lo.: 0 V output
Measurement items
Rectifier
Rated output voltage
AC+DC
AC+DC
+Umn
DC AC FND
Voltage V
Relative to ±100% of the range
STD.2: ±2 V DC
STD.5: ±5 V DC
Current A
Active power W
Apparent power VA Lo.
Reactive power var Lo.
Power factor PF Lo.
STD.2: ±2 V DC at ±0.0000,
±0 V DC at ±1.0000
STD.5: ±5 V DC at ±0.0000,
±0 V DC at ±1.0000
Phase angle ° Lo. Lo. Lo.
STD.2: ±0 V DC at 0.00°,
±2 V DC at ±180.00°
STD.5: ±0 V DC at 0.00°,
±5 V DC at ±180.00°
Frequency
VHz
AHz
−−−−−
5 V at set value
Example: If set to 5 kHz,
5 V DC at 5 kHz
Time average
current
T.AV A * * Lo. Lo.
Relative to ±100% of the range
STD.2: ±2 V DC
STD.5: ±5 V DC
Time average
active power
T.AV W Lo. Lo.
Current integration
Ah+
Ah-
Lo. Lo. Lo. Lo.
5 V when set value is reached
Example: If set to 5 kAh,
5 V DC at 5 kAh
Ah * * Lo. Lo.
Active power
integration
Wh+
Wh-
Wh
Lo. Lo.
5 V when set value is reached
Example: If set to 5 kWh,
5 V DC at 5 kWh
Crest factor
CF V
CF A
−−−−−
STD.2: ±2 V DC at 10.000
STD.5: ±5 V DC at 10.000
Ripple rate
RF V%
RF A%
−−−−−
STD.2: ±2 V DC at 100.00%
STD.5: ±5 V DC at 100.00%
Total harmonic
distortion
THD V%
THD A%
−−−−−
Maximum current
ratio
MCR −−−−−
S
TD.2: ±2 V DC at 10.000
STD.5: ±5 V DC at 10.000