Installation GRS1020/1120/1030/1130
Release
03
01/2017
7 Technical data
General technical data
Dimensions
W × H × D
GRS1020- 17.64 in. × 12.40 in. × 1.73 in. (448 mm ×
315 mm × 44 mm)
(without brackets)
GRS1120-
GRS1030-
GRS1130-
Weight
Supply voltage
with the
characteristic
value M
GRS1020-16T9 8.16 lb (3.7 kg)
GRS1120-16T9
GRS1030-16T9 8.38 lb (3.8 kg)
GRS1130-16T9
GRS1020-8T8Z 7.94 lb (3.6 kg)
GRS1120-8T8Z
GRS1030-8T8Z 8.16 lb (3.7 kg)
GRS1130-8T8Z
Optional second power unit Additional 12.22 oz
(380 g)
Weight
Supply voltage
with the
characteristic
value C
GRS1020-16T9 8.38 lb (3.8 kg)
GRS1120-16T9
GRS1030-16T9 8.38 lb (3.8 kg)
GRS1130-16T9
GRS1020-8T8Z 7.94 lb (3.6 kg)
GRS1120-8T8Z
GRS1030-8T8Z 8.16 lb (3.7 kg)
GRS1130-8T8Z
Optional second power unit Additional 13.83 oz (430 g)
Power supply
Supply voltage
with the
characteristic
value M
Nominal voltage AC 110 V ... 240 V, 50 Hz ... 60 Hz
Voltage range AC incl.
maximum tolerances
88 V ... 276 V
Connection type 3-pin terminal block
Nominal voltage DC 110 V ... 250 V
Voltage range DC incl.
maximum tolerances:
88 V ... 288 V
Power loss buffer > 20 ms at 230 V AC
Back-up fuse for each voltage
input
Nominal rating:
Characteristic:
2.5 A
slow blow
Overload current protection at
input
Non-replaceable fuse
Peak inrush current < 6 A