9.TROUBLE SHOOTING
31
HEATING ERROR
Yes
Is the connector connected
to heater disconnected or
disassembled?
Yes
No
Reconnect
or repair the
connector
Is Check heater resistance
out of range? (33.5-37 )
(
Refer to 9-6
)
No
Yes
Replace the
heater
Is the voltage of the heater
connector 220-240 V?( while
the power is on)
Yes
No
Replace the
PCB
Is Electrical connection
correct?(Refer to 10-6)
Replace the
main harness
No
Yes
Is the connector connected
to PCB disconnected or dis-
assembled?
Reconnect
or repair the
connector
Yes
No
Replace the PCB
[Note] Environmental safety check list
Chances that the cause occurs from the main
controller are very little. Sensing part of the circuit
(tE) consists of only resistors and capacitors.
DOOR LOCK ERROR
[Note] Environmental safety check list
1) The machine must operate with all the doors
completely closed and locked.
2) The washing area must operate with a water
temperature not higher than 50 and must not
have more amount of supplied water than it should.
Yes
Is the connector connected
to door lock or PCB
disconnected?
Yes
No
Reconnect
or repair the
connector.
Is the voltage of the heater
connector 220-240 V when
the start/pause button is
pressed to start the cycle?
No
Yes
Replace the
PCB
Is door lock broken?
Replace the
door lock
Yes
Does the spring of latch
hook actuate?
Replace Door
A
ssembly
No
Yes

Related product manuals