3. FEATURES & TECHNICAL EXPLANATION
7
In order to avoid the user to falsely triggering the “Off” position of the knob, 3
successive seconds are required for switching from “On mode” to “Off mode”,
and only one click is required for switching from “Off mode” to “On mode”.
3.4 WATER LEVEL CONTROL
This module contains a FWL sensor for detecting the water level of tub.
During water inflowing, the PCB controls the inlet valve to function and execute
the water inflow operation. When the water level reaches the “Washing water
level”, the water inflow stops and the washing process begins. If the water level
declines during washing, it will automatically activate the water inflow and
replenishing program so as to reach the “Washing water level” again.
During water draining, the PCB controls the draining pump to continuously
work and begin the water draining process. When the water of tub is discharged
down to the “Spinning water level”, the Spinning process will begin.
3.5 DOOR LOCK CONTROL
When the PCB enters in “Ready mode”, it will detect the state of door lock and
execute operation accordingly. When the door is unlocked, no operation is done
if the unlocking conditions are satisfied, otherwise, the door should be locked;
when the door is locked, execute unlocking operation if the unlocking conditions
are satisfied, otherwise, the door should be maintained locked.
After selecting the program and function, press the “Start/Pause” button, the
PCB controls the door lock to execute locking operation, and the “Door lock”
icon on display window is on.
After the program ends, the “Door lock” icon on display window is flickering
when the unlocking conditions are satisfied, and the PCB controls the door lock
to execute unlocking operation. When the “Door lock” icon on display window is