EasyManua.ls Logo

Hitachi Compute Blade 500 Series - HDD Slot, Order of Installation, and Indicator; HDD Slot and Order of Installation

Hitachi Compute Blade 500 Series
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Location Name State Description
10 QPI Link Status LED (LNK) Green-On QPI is linked in SMP
configuration.
11 Diagnostic Panel LP Green-On The LED panel is active.
S BRD Amber-On The motherboard needs to
be replaced.
MIS Amber-On Unsupported combination
of the DIMM, CPU, and
HDD.
NMI Amber-On A Non-Maskable Interrupt
(NMI) was generated.
TEMP Amber-On The maximum temperature
limit was exceeded.
MEM Amber-On A memory failure was
detected.
ADJ - Not supported.
Notes:
1. When using the USB port of KVM cable except keyboard and mouse, you should use
the device with a rated maximum current limit 500 mA per two ports, or the USB
device that can be external powered.
2. When POWER LED starts blinking from lighting solid, release the button. If you press
the power switch for six seconds or more, the power may turn on after forced turn-
off. If so, check that HDD access LED is not illuminated, and then press and hold the
power button for four seconds or more.
3. Error cannot be displayed while from pressing the power button until turning on the
main power.
HDD slot, order of installation, and indicator
HDD slot and order of installation
Figure 1-22 Half-wide Blade
System Overview
1-21
Hitachi Compute Blade 500 Series System Overview Guide

Table of Contents

Other manuals for Hitachi Compute Blade 500 Series

Related product manuals