11
Restoring Factory Default Settings
Note: After initializing the inverter, use the Powerup Test on
page 8 to get the motor running again.
Action Display Function/Parameter
Press , or as
needed.
b
–––
“B” Group selected
Press .
b
001
First “B” Group parameter
Press/hold until...
b
085
Country code for
initialization selected
Press . If setting is
correct, then skip next step.
02
00 = Japan
01 = Europe
02 = USA
To change country code, press
or to set; to store.
Press .
b
085
Country code for
initialization selected
Press .
b
084
Initialization function
selected
Press .
00
00 = disable initialization,
clear trip history only
Press .
01
01 = enable initialization
Press .
b
084
Initialization now enabled
to restore all defaults
Press/hold , , ,
and keys. Do not release
yet.
b
084
First part of key sequence
When your country code
appears in the display, release
all the keys.
EU
USA
JP
Default parameter country
code shown during initial-
ization
Initialization is complete.
d
001
Function code for output
frequency monitor shown
FUNC.
1
2
FUNC.
1
FUNC.
1
2
STR
FUNC.
2
FUNC.
1
STR
FUNC.
1
2
STOP
RESET