18
Holding Register data configuration (4/13)
Word
address
Classification Item name Setting range Contents
10 58
Print format
Print format(Print item 2)
-
Item 2 through 50 will be set in the
same configuration as those of
Item 1 (Address: from 0x1040 to
0x1057).
10 6F
… …
14 D8
Print format(Print item 50)
14 EF
14 F0 Reserve_1
-
"Reserve" is not initially provided,
but may be added in future.
… …
19 9F Reserve_1200
19 A0
Print
specification
Character height 0 to 99 Sets the character height.
19 A1 Ink drop use 1 to 16 Sets the ink drop use.
19 A2 High-speed print 0 to 3
Sets the high-speed print.
0:HM , 1:NM , 2:QM , 3:SM
19 A3 Character width 0 to 3999 Sets the character width.
19 A4 Character orientation 0 to 3 Sets the character orientation.
19 A5 Print start delay 0 to 9999 Sets the print start delay.
19 A6 Reverse direction 0 to 9999 Sets the reverse direction.
19 A7 Product speed matching 0 to 3
Sets the product speed matching.
0:None , 1:Encoder , 2:Auto
3:Encoder(enhance)
19 A8 Pulse rate division factor 1 to 999 Sets the pulse rate division factor.
19 A9 Speed compensation 0 , 1
Sets the speed compensation.
0:Disable , 1:Enable
19 AA Line speed 0 to 9999
Sets the line speed.
Set value is multiplied by 1/10 and
reflected to IJ Printer. .
(Example : 1234 = 123.4 m/min.)
19 AB
Distance between print head
and work
0 to 99
Sets the distance between print
head and work.
19 AC Print Target width 0 to 9999 Sets the print Target width.
19 AD Actual Print width 0 to 9999 Sets the actual Print width.
19 AE Repeat count 0 to 9999 Sets the repeat count.
19 AF
Repeat intervals 0 to 99999 Sets the repeat intervals.
19 B0
19 B1 Target sensor timer 0 to 999 Sets the target sensor timer.
19 B2 Target sensor filter 0 , 1
Sets the target sensor filter.
0:Time setup , 1:Until end of print.
19 B3 Target sensor filter value 0 to 9999 Sets the target sensor filter value.
19 B4 Ink Drop Charge Rule 0 to 2
Sets the ink drop charge rule.
0:Standard
1:Mixed single scan and interlaced
2:Dot mixed interlaced
19 B5
Speed compensation fine
control
-50 to 50
Sets the speed compensation fine
control.
19 B6 Reserve_1
-
"Reserve" is not initially provided,
but may be added in future.
… …
19 BF Reserve_10