State Controller FMD drive
900
(Environmental
temperature:
10°C to 40°C)
900 (Environmental temperature: 10°C to 40°C) when
DKC-F810I-1R6FN/3R2FN/6R4FN/7R0FP/14RFP drive is
installed.
Non-operating
(m)
-60 to 12,000 N/A
State Controller SFF and LFF drives
Dense intermix
drive tray
Operating (m)
3,000
(Environmenta
l temperature:
10°C to 32°C)
3,000 (Environmental temperature: 10°C to
32°C)
3,000
(Environmental
temperature:
10°C to 28°C)
1,000
(Environmental
temperature:
10°C to 35°C)
900
(Environmenta
l temperature:
10°C to 40°C)
900 (Environmental temperature: 10°C to
40°C)
Non-operating
(m)
N/A
Atmosphere
Avoid areas exposed to corrosive gas and salty air.
Acoustic Noise
State Controller SFF, LFF Dense intermix drive tray
Operati
ng
60 dB (Environmental temperature
32°C or less)
1
60 dB
(Environmental
temperature
32°C or less)
1
71 dB (Environmental
temperature 32°C or less)
1
,
2
,
3
,
4
Non-
operati
ng
55 dB 55 dB 71 dB (Environmental
temperature 32°C or less)
1
,
2
,
3
,
4
Notes:
1. The system's internal temperature controls the rotating speed of the fan module. Therefore,
this standard value might be exceeded if the maximum load continues under high-
temperature environment or if a failure occurs in the system.
2. Sound pressure level (LA) changes from 66 dB or 75 dB, according to the ambient
temperature, drive configuration, and operating status. Maximum volume can reach 79 dB
during maintenance procedure for a failed ENC or power supply.
3. Acoustic power level (LwA) measured by the ISO 7779 standard is 7.2 B. This value changes
from 7.2 B to 8.1 B, according to the ambient temperature, drive configuration, and operating
status.
4. When accessing the dense intermix drive tray, do not work for long times at the rear of the
rack.
96 Environmental specifications for VSP G400, G600
Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide