73
Input Function Summary Table
Option
Code
Terminal
Symbol
Function Name
Description

BOK
Brake confirmation
ON
Brake wait time () is valid
OFF
Brake wait time () is not valid

LAC
LAD cancellation
ON
Set ramp times are ignored. Inverter output
immediately follows the freq. command.
OFF
Accel. and/or decel. is according to the
set ramp time

ADD
ADD frequency enable
ON
Adds the  (add frequency) value
to the output frequency
OFF
Does not add the  value to the
output frequency

F-TM
Force Terminal Mode
ON
Force inverter to use input terminals
for output frequency and Run command sources
OFF
Source of output frequency set by  and source
of Run command set by  is used

KHC
Clear watt-hour data
ON
Clear watt-hour data
OFF
No action

MI1
General purpose input
(1)
ON
General purpose input (1) is made ON under EzSQ
OFF
General purpose input (1) is made OFF under EzSQ

MI2
General purpose input
(2)
ON
General purpose input (2) is made ON under EzSQ
OFF
General purpose input (2) is made OFF under EzSQ

MI3
General purpose input
(3)
ON
General purpose input (3) is made ON under EzSQ
OFF
General purpose input (3) is made OFF under EzSQ

MI4
General purpose input
(4)
ON
General purpose input (4) is made ON under EzSQ
OFF
General purpose input (4) is made OFF under EzSQ

MI5
General purpose input
(5)
ON
General purpose input (5) is made ON under EzSQ
OFF
General purpose input (5) is made OFF under EzSQ

MI6
General purpose input
(6)
ON
General purpose input (6) is made ON under EzSQ
OFF
General purpose input (6) is made OFF under EzSQ

MI7
General purpose input
(7)
ON
General purpose input (7) is made ON under EzSQ
OFF
General purpose input (7) is made OFF under EzSQ

AHD
Analog command hold
ON
Analog command is held
OFF
Analog command is not held

GS1
GS1 input
ON
EN60204-1 related signals:
Signal input of Safe torque off function.
OFF

GS2
GS2 input
ON
OFF

485
Start EzCOM
ON
Starts EzCOM
OFF
No execution

PRG
Executing EzSQ
program
ON
Executing EzSQ program
OFF
No execution

HLD
Retain output frequency
ON
Retain the current output frequency
OFF
No retention

ROK
Permission of Run
command
ON
Run command permitted
OFF
Run command is not permitted

DISP
Display limitation
ON
Only a parameter configured in  is shown
OFF
All the monitors can be shown

no
No function
ON
(input ignored)
OFF
(input ignored)