Input Function Summary Table
Brake wait time () is valid
Brake wait time () is not valid
Set ramp times are ignored. Inverter output
immediately follows the freq. command.
Accel. and/or decel. is according to the
set ramp time
Adds the (add frequency) value
to the output frequency
Does not add the value to the
output frequency
Force inverter to use input terminals
for output frequency and Run command sources
Source of output frequency set by and source
of Run command set by is used
General purpose input
(1)
General purpose input (1) is made ON under EzSQ
General purpose input (1) is made OFF under EzSQ
General purpose input
(2)
General purpose input (2) is made ON under EzSQ
General purpose input (2) is made OFF under EzSQ
General purpose input
(3)
General purpose input (3) is made ON under EzSQ
General purpose input (3) is made OFF under EzSQ
General purpose input
(4)
General purpose input (4) is made ON under EzSQ
General purpose input (4) is made OFF under EzSQ
General purpose input
(5)
General purpose input (5) is made ON under EzSQ
General purpose input (5) is made OFF under EzSQ
General purpose input
(6)
General purpose input (6) is made ON under EzSQ
General purpose input (6) is made OFF under EzSQ
General purpose input
(7)
General purpose input (7) is made ON under EzSQ
General purpose input (7) is made OFF under EzSQ
Analog command is not held
EN60204-1 related signals:
Signal input of “Safe torque off” function.
Retain the current output frequency
Permission of Run
command
Run command is not permitted
Only a parameter configured in is shown
All the monitors can be shown