- 8 -
Error Trip Conditions
Use function code d081 to access the error trip conditions for the current
error as shown in the table below. Use the Up and Down arrow keys to
scroll through the trip condition parameters.
Step Display
1. Access d081
d081
If no error:
_ _ _
2. Press Function Key
If error exists:
E_xx
(error code)
3. Press Up/Dn key
(if error exists)
Output frequency at trip point:
48.50
Motor current at trip point:
10.3
DC bus voltage at trip point:
189.5
Cumulative Run hours at trip point:
15
Cumulative power-ON hours at trip point:
18
2
1