Loading...
- 9 -
Restoring Factory Default Settings
Action Display Function/Parameter
Press , or as
needed
b- - -
“B” Group selected
Press
b001
First “B” Group parameter
Press/hold until…
b085
Country code for
initialization selected
Press . If setting is
correct, then skip next step.
02
00 = Japan
01 = Europe
02 = United States
To change country code, press or to set; to store.
Press
b085
Country code for
initialization selected
Press
b084
Initialization function
selected
Press
00
00 = disable initialization
Press
01
01 = enable initialization
Press
b084
Initialization now enable to
restore all defaults
Press/hold , and
keys. Do not release yet.
b084
First part of key sequence
When your country code
appears in the display, release
all the keys.
EU
USA
JP
Default parameter country
code shown during
initialization
Initialization is complete.
d001
Function code for output
frequency monitor shown
Note: After initializing the inverter, use the Powerup Test on
page 6 to get the motor running again.
2
1
FUNC
FUNC
1
FUNC
2
1
STR
FUNC
2
FUNC
1
STR
2
FUNC
STOP
RESET

Other manuals for Hitachi X200 Series

Related product manuals