EasyManua.ls Logo

Hitachi X200 Series - Page 120

Hitachi X200 Series
305 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
“B” Function Defaults
Func.
Code
Name /
SRW Display
Description
Run
Mode
Edit
-FE
(EU)
-FU
(USA)
Units
Software lock mode selectionB031
S-Lock MD1
Prevents parameter changes, in
four options, option codes:
00}all parameters except B031
are locked when [SFT]
terminal is ON
01}all parameters except B031
and output frequency F001
are locked when [SFT]
terminal is ON
02}all parameters except B031
are locked
03}all parameters except B031
and output frequency F001
are locked
10}High level access including
B031
See appendix C for the accessible
parameters in this mode.
U
01 01
NOTE: To disable parameter editing when using B031 lock modes 00 and 01, assign the
[SFT] function to one of the intelligent input terminals.
See “Software Lock” on page 4-21.