EasyManuals Logo

Hitachi X200 Series User Manual

Hitachi X200 Series
305 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
Index to Warnings and Cautions in This Manual iv
Cautions and Warnings for Orientation and Mounting Procedures
HIGH VOLTAGE: Hazard of electrical shock. Disconnect incoming power before
working on this control. Wait five (5) minutes before removing the front cover.
H
IGH VOLTAGE:Hazard of electrical shock. Never touch the naked PCB
(printed circuit board) portions while the unit is powered up. Even for switch
portion, the inverter must be powered OFF before you change.
WARNING: In the cases below involving a general-purpose inverter, a large peak
current can flow on the power supply side, sometimes destroying the converter module:
1. The unbalance factor of the power supply is 3% or higher.
2. The power supply capacity is at least 10 times greater than the inverter capacity (or
the power supply capacity is 500kVA or more).
3. Abrupt power supply changes are expected, due to the conditions such as:
a. Several inverters are interconnected with a short bus.
b. A thyristor converter and an inverter are interconnected with a short bus.
c. An installed phase advance capacitor opens and closes.
C
AUTION: Be sure to install the unit on flame-resistant material such as a steel plate.
Otherwise, there is the danger of fire.
C
AUTION: Be sure not to place any flammable materials near the inverter. Otherwise,
there is the danger of fire.
C
AUTION: Be sure not to let the foreign matter enter vent openings in the inverter
housing, such as wire clippings, spatter from welding, metal shavings, dust, etc.
Otherwise, there is the danger of fire.
C
AUTION: Be sure to install the inverter in a place that can bear the weight according
to the specifications in the text (Chapter 1, Specifications Tables). Otherwise, it may fall
and cause injury to personnel.
C
AUTION: Be sure to install the unit on a perpendicular wall that is not subject to
vibration. Otherwise, it may fall and cause injury to personnel.
C
AUTION: Be sure not to install or operate an inverter that is damaged or has missing
parts. Otherwise, it may cause injury to personnel.
C
AUTION: Be sure to install the inverter in a well-ventilated room that does not have
direct exposure to sunlight, a tendency for high temperature, high humidity or dew
condensation, high levels of dust, corrosive gas, explosive gas, inflammable gas,
grinding-fluid mist, salt damage, etc. Otherwise, there is the danger of fire.
C
AUTION: Be sure to maintain the specified clearance area around the inverter and to
provide adequate ventilation. Otherwise, the inverter may overheat and cause
equipment damage or fire.
…2-3
…2-4
…2-8
…2-9
…2-9
…2-9
…2-9
…2-9
…2-9
…2-9
…2-10
iv
iv

Table of Contents

Other manuals for Hitachi X200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi X200 Series and is the answer not in the manual?

Hitachi X200 Series Specifications

General IconGeneral
SeriesX200
Output Frequency0-400 Hz
Cooling MethodFan Cooled
TypeInverter
Control MethodV/F control
Overload Capacity150% for 60 seconds
Braking UnitBuilt-in
CommunicationRS485, Modbus RTU
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
Ambient Temperature-10°C to +50°C
Humidity5 to 95% RH (Non-condensing)
Enclosure RatingIP20
Operating Temperature-10°C to +40°C
Storage Temperature-20°C to +60°C

Related product manuals