C102 Reset selection Determines response to Reset input
[RS].
Three option codes:
00}Cancel trip state at input
signal ON transition, stops
inverter if in Run Mode
01}Cancel trip state at signal OFF
transition, stops inverter if in
Run Mode
02}Cancel trip state at input ON
transition, no effect if in Run Mode
114Ah 0, 1, 2
C141 Input A select for logic
output
R/W 1150h
C142 Input B select for logic
output
R/W
See “Output Logic and Timing” on
page 3–63
1151h
0, 1, 2, 3,
4, 5, 6, 7,
8, 10, 43
C143 Logic function select R/W Applies a logic function to calculate
[LOG] output state, Three options:
00}[LOG] = A AND B
01}[LOG] = A OR B
02}[LOG] = A XOR B
1152h 0, 1, 2