Advanced System Set Up
The system will be set to its default parameters when powered on for the rst
time. The screen displays the following information in sequence and the user can
change any given value on each screen.
To change a parameter value in the program, press START/ENTER to make that
value blink. Next, change the value by pressing INC or DEC. The value will be
stored by pressing START/ENTER once.
When you start a charge process, the integral
safety timer automatically starts running at
the same time. This is programmed to prevent
overcharging of the battery if it proves to be
faulty, or if the termination circuit cannot detect
the battery full. The value for the safety timer
should be generous enough to allow a full
charge battery.
OFF/ON
(1-720 Min)
Default: 120 min
OFF/ON
(100-50000mAh)
Cut-off : 5000mAh
OFF/ON
(20
0
C/68
0
F -
80
0
C/176
0
F)
Celsius
Fahrenheit
1-60 Min
Selection
Description
Item
The battery’s internal chemical reaction
will cause the temperature of the battery
to rise. If the temperature limit is reached,
the process will be terminated.
You can choose the temperature
displayed by Celsius or Farenheit as
you like.
A rest time allows the battery to
cool down between charging/
discharging cycle.
This program sets the maximum charge
capacity that will be supplied to the
battery during charge. If the delta peak
voltage is not detected, the safety will
automatically stop the process at the
selected capacity value.
Safety Timer
ON 120 Min
Capacity Cut-Off
ON 5000mAh
Temp Cut-off
ON 50
0
C 122
0
F
Temperature Unit
Celsius
Rest Time
CHG > DCHG 10Min