14
Battery Type Operation Operation Description
NiMH
NiCd
CHARGE
The charger will charge NiMH and NiCd batteries
using the charge current set by the user.
AUTO CHG
In this program, the charger detects the condition
of the connected battery and automatically
charges the battery.
Note: You should set the upper limit of the charge
current to avoid damage by excessive charging current.
The RDX1 Pro may not be able to detect the charge
capacity of low resistance batteries.
DISCHARGE
This mode is for discharging a NiMH/NiCd battery
RE-PEAK
In re-peak charge mode, the charger can peak
charge the battery once, twice, or three times in a
row automatically. This is good for con rming the
battery is fully charged and for checking how well
the battery receives fast charges.
CYCLE
Automatically charges/discharges the battery
up to 5 times. This process can enhance the
performance of NiMH/NiCd batteries.
Lead
Acid
Pb
CHARGE
This mode is for charging a Pb battery.
DISCHARGE
This mode is for discharging a Pb battery.
Available Operations (continued)
The following is a step-by-step guide for operating the RDX1 Pro. The screen
shots and operation templates shown below are for the operation of a LiPo
BALANCE CHARGE program . Refer to the Available Operations chart on
page 13 and 14 to setup your speci c type of battery.
Operating the Charger