OPERATION
HOLZMANN Maschinen Austria www.holzmann-maschinen.at Seite 46
5-fach Kombination / combined 5-operation machine K5 260L
4-wire:
without
N-conductor
13.2.5 Control
After connection to the power grid, it is necessary to check the direction of the saw blade. To do this,
start the engine briefly. If the blade rotates in the wrong direction, you have to fix the direction of two
cord ends.
13.3 Prior to the commissioning
Before any adjustments, the machine must be disconnected from the power supply to avoid
the risk of accidental switching on the machine!
Check that the set speed for the saw blade used is not too high.
Span only saw blades with a diameter of max. 254 mm.
13.3.1 Setting the riving knife
The riving knife is adjusted according to the size of the saw blade.
by removing the appropriate screws and align the riving knife as
specified by a.
gap wedge distance from the circular saw blade set as low as
possible. Distance of less than 8 mm
riving knife set approximately 2 mm below the highest saw-
tooth.
After setting to the correct distance you pull the screws firmly.
14 OPERATION
14.1 Notes on Operation
Set the protective cover of the circular saw blade.
Run the workpiece evenly without flare-ups and without take it back to the end of cutting to.
Set the circular saw blade so high that the ring gear is really reliably covered by the protective
cover (distance between the protective cover and the workpiece - max 5 mm.