4 - 3
Function Code Transmit
When this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function 
code to the terminal.  Charts of these function codes are provided in Supported Interface Keys starting on page 7-3.  When the 
scanner is in keyboard wedge mode, the scan code is converted to a key code before it is transmitted. Default = Enable.
Intercharacter, Interfunction, and Intermessage Delays
Some terminals drop information (characters) if data comes through too quickly.  Intercharacter, interfunction, and intermessage 
delays slow the transmission of data, increasing data integrity.
Intercharacter Delay
An intercharacter delay of up to 5000 milliseconds (in 5ms increments) may be placed between the transmission of each 
character of scanned data.  Scan the Intercharacter Delay bar code below, then scan the number of 5ms delays, and the 
Save bar code using the Programming Chart inside the back cover of this manual.
To remove this delay, scan the Intercharacter Delay bar code, then set the number of delays to 0.  Scan the Save bar code 
using the Programming Chart inside the back cover of this manual.
Note: Intercharacter delays are not supported in USB serial emulation.
User Specified Intercharacter Delay
An intercharacter delay of up to 5000 milliseconds (in 5ms increments) may be placed after the transmission of a particular 
character of scanned data.  Scan the Delay Length bar code below, then scan the number of 5ms delays, and the Save 
bar code using the Programming Chart inside the back cover of this manual. 
1 2345
Intercharacter Delay
Prefix Scanned Data Suffix
Intercharacter Delay