Accenta/Optima Engineers Manual
32
LED Keypad:
Press to toggle double knock status on or off.
Press [9] to turn all double knock zones on.
Press [0] to turn all double knock zones off.
Press to enter into menu. LED’s 1 and 2 are on.
Press [1] to select Double Knock.
Press zone number [1-8] to choose a particular zone.
Press the zone [number] or to toggle the double knock
status on or off. The appropriate LED is on when the zone is
set up as Double Knock. Default settings are off.
Press twice to leave the menu.
2 = Omit Allow
When a zone is programmed as Omit Allow, the panel allows the zone to be omitted for one set period by the
user when setting the system.
Programming a Zone as Omit Allow
The [up arrow] scrolls through zones.
Press to toggle omit allow status on or off.
Press [9] to turn all omit allow zones on.
Press [0] to turn all omit allow zones off.
LCD Keypad:
While in Engineer program mode press or press until
0>Omit allow & Double Knock is displayed then press .
Press [2] to select Omit Allow. The first zone is
displayed with status on or off.
Press the [zone number] or to toggle the
status on or off.
Press the or [zone number] to go to the
other zones and follow the same procedure as above.
Press twice to leave the menu.
Omit Allow & Double Knock
[1]
12
3
4
5
6
7
8
[1-8] or
12
3
4
5
6
7
8
12
3
4
5
6
7
8
12
3
4
5
6
7
8
1. Double Knock
2. Omit Allow
[2]
Omit Allow &
Double Knock
2: <Zone Name>
Omit Allow:NO
2: <Zone Name>
Omit Allow:YES
[zone number] or