Accenta/Optima Engineers Manual
39
5 = Exit Time
This is the time allowed to leave the premises via the exit route before the system sets. The programmable
range is 00-99 seconds. The actual time is multiplied by 10.
If the Exit Time is interrupted within the last 10 seconds, then the Exit Time will restart at 10 seconds after
the interruption has cleared.
00 = 5 seconds
01 = 10 seconds
03 = 30 seconds
99 = 990 seconds (16.5 minutes)
The default is 30 seconds.
LCD Keypad:
While in Engineer program mode, to set the Exit Time,
Press to give a choice of programs or press until
P>Programs is displayed then press .
Select program 1, 2 or 3.
The first screen to appear is Program Edit Used Zones.
Press [5] to enter into Exit Time edit. The Exit Time
can now be changed.
Enter a [2-digit number] from 00 to 99.
Press to accept change or to cancel.
Press twice to leave menu.
LED Keypad:
While in Engineer program mode, to set the Exit Time,
Press to give a choice of programs.LED’s 1, 2 and 3 are
flashing.
Select program 1, 2 or 3. If program 2 is selected, LED 2 is ON.
Select [4] to enter into Exit Time edit. The Exit Time can now
be changed. LED 2 is ON.
Enter a [2-digit number] from 00 to 99. LED 2 is ON.
Press to accept change or to cancel.
Press twice to leave menu.
Programs (contd)
[4]
P>Program Edit
Exit Time? --
P>Select Program
1 2 or 3
P>Program Edit
Used Zones
[Number]
[2-digit number] then or
P>Program Edit
Exit Time
P>Programs
[2]
[4]
12
3
4
5
6
7
8
[2-digit number] then
or
12
3
4
5
6
7
8
12
3
4
5
6
7
8
12
3
4
5
6
7
8
12
3
4
5
6
7
8

Other manuals for Honeywell Accenta

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Accenta and is the answer not in the manual?

Honeywell Accenta Specifications

General IconGeneral
Tamper CircuitYes
Event LogYes
Battery BackupYes
KeypadWired
Power Supply230V AC, 12V DC

Related product manuals