Safety SmartRadar FlexLine
Installation Guide Part No.: 4417.760_Rev06
12
3 Sight glasses shall be coated with a microwave proof coating
when necessary (i.e. electrically conductive coating).
4 Manholes or connection flanges at the tank shall be closed to
ensure a low-level leakage of the signal into the air outside the
tank.
5 Whenever possible, mounting of the radar equipment shall be on
top of the tank structure with the orientation of the antenna to
pointing in a downward direction.
6 Installation and maintenance of the radar equipment shall be
performed by professionally trained individuals only.