EasyManua.ls Logo

Honeywell Enraf SmartRadar FlexLine - MPT - MRT Connection; Stand-alone SmartView Display Wiring

Honeywell Enraf SmartRadar FlexLine
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation SmartRadar FlexLine
Installation Guide Part No.: 4417.760_Rev06
40
4.11.4.3.3 MPT - MRT (Board ID = 4)
4.11.4.4 Stand-alone SmartView Display
The labelling on the wiring terminal in the SmartView is identical
to the labelling in the SmartRadar.
Label Connections diagram Parameters
38. S- [Ex ia] IIB/IIC
U
o
= 8.61 V
I
o
= 58 mA
P
o
= 0.13 W
C
o
= 1.0 μF
L
o
= 10.5 mH
39. com
40. R1
41. R2
42. R3
43. R4
44. R5
45. R6
Cable specifications
Type 4-wire, shielded
Maximum length 50 meter
Label Parameters
26. SGND [Ex ia] IIB
U
o
= 14.2 V
I
o
= 522 mA
P
o
= 1.7W
C
o
= 2.18 μF
L
o
= 0.25 mH
27. Vsafe_+
28. Safe_A
29. Safe_B
R
c
R1
R2
R3
R4
R5
R6

Table of Contents

Related product manuals