Ev SIA Event Galaxy Log Galaxy Log Event Ev Type Galaxy Contact
Description Event Description Trigger ID Event
E - System Trouble
ER Mod Removed REMOVED Module Removed MOD TAMPER 532
ET RF NVM Fail RF MEM! RF NVM RAM Fail MOD TAMPER 333
F - Fire
FA Fire Alarm FIRE+ Fire zone alarm ZONE 6.FIRE 110
FB Fire Bypass OMITTED Fire zone ommitted ZONE 8.OMIT 573
FORCEOMT+ Force omit after rearm ZONE 8.OMIT 573
FJ Fire Troub rest LOW RES- Restor zone resistance ZONE 15.TROUBL 380
HIGH RES- Restor zone resistance ZONE 15.TROUBL 380
FR Fire Restoral FIRE- Fire zone restored ZONE 6.FIRE 110
18.ZN RESTO
FT Fire Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL 380
HIGH RES+ High resistance on zone ZONE 15.TROUBL 380
FU Fire Unbypass FORCE OMT- Unomitted after rearm ZONE 8.OMIT 573
FX Fire Test FIRE Fire zone tested ZONE NOT SENT None
SOAK TEST Soak test fire zone act ZONE NOT SENT None
G - Gas (Custom SIA - See Note 2)
GA Alarm Note 1 zone in alarm ZONE 5.CUS ZON Note 1
GB Bypass OMITTED zone ommitted ZONE 8.OMIT Note 1
FORCEOMT+ Force omit after rearm ZONE 8.OMIT Note 1
GJ Trouble Rest LOW RES- Restor zone resistance ZONE 15.TROUBL Note 1
HIGH RES- Restor zone resistance ZONE 15.TROUBL Note 1
GR Alarm Restore Note 1 zone restored ZONE 5.CUS ZON Note 1
18.ZN RESTO
GT Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL Note 1
HIGH RES+ High resistance on zone ZONE 15.TROUBL Note 1
GU Unbypass FORCE OMT- Unomitted after rearm ZONE 8.OMIT Note 1
H - Holdup
HA Holdup Alarm PA SILENT+ PA Silent zone alarm ZONE 1.PA/DURE 122
PA DEL/SL+ PA Delay Sil.zone alarm ZONE 1.PA/DURE 122
DURESS Duress with code USER 1.PA/DURE 121
PA UNSET+ PA Unset zone alarm ZONE 1.PA/DURE 122
HB Holdup Bypass OMITTED Holdup zone omitted ZONE 8.OMIT 573
FORCEOMT+ Force omit after rearm ZONE 8.OMIT 573
HJ Hold Troub rest LOW RES- Restor zone resistance ZONE 15.TROUBL 380
HIGH RES- Restor zone resistance ZONE 15.TROUBL 380
HR Hold Restoral PA SILENT- PA Silent zone restored ZONE 1.PA/DURE 122
18.ZN RESTO
PA DEL/SL- PA Delay Sil.zone rest. ZONE 1.PA/DURE 122
18.ZN RESTO
PA UNSET- PA Unset zone restored ZONE 1.PA/DURE 122
18.ZN RESTO
HT Holdup Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL 380
HIGH RES+ High resistance on zone ZONE 15.TROUBL 380
HU Hold Unbypass FORCE OMT- Unomitted after rearm ZONE 8.OMIT 573
Event Codes (cont’d)

Table of Contents

Other manuals for Honeywell Galaxy 3-48C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy 3-48C and is the answer not in the manual?

Honeywell Galaxy 3-48C Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy 3-48C
CategorySecurity System
LanguageEnglish

Related product manuals