Galaxy 3 Series Programming Manual
B-6
Ev SIA Event Galaxy Log Galaxy Log Event Ev Type Galaxy Contact
Description Event Description Trigger ID Event
J - Wrong code, Time changed
JA Code Tamper WRONG CD Wrong code alarm act. MOD. 9.TAMPER 461
Invalid Code INVALID CD Invalid Code entered MOD. ALWAYS TR None
JL LOG 90% MISC Always TR 632
JR TIMER A MISC NONE 0
TIMER B MISC NONE 0
AUTOTIMER MISC NONE 0
LOCKTIMER MISC NONE 0
JT Time changed NEW T/D Time/Date modified USER ALWAYS TR
3
625
K - Heat (Custom SIA - See Note 2)
KA Alarm Note 1 zone in alarm ZONE 5.CUS ZON Note 1
KB Bypass OMITTED zone ommitted ZONE 8.OMIT 573
FORCEOMT+ Force omit after rearm ZONE 8.OMIT 573
KJ Trouble Rest LOW RES- Restor zone resistance ZONE 15.TROUBL 380
HIGH RES- Restor zone resistance ZONE 15.TROUBL 380
KR Alarm Restore Note 1 zone restored ZONE 5.CUS ZON Note 1
18.ZN RESTO
KT Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL 380
HIGH RES+ High resistance on zone ZONE 15.TROUBL 380
KU Unbypass FORCE OMT- Unomitted after rearm ZONE 8.OMIT 573
L - Phone, Program
LB Program begin ENGINEER+ Engineer mode entered MISC ALWAYS TR 627
TEST O/P USER NONE 0
FULL TEST SET NONE 0
MOD T/D USER NONE 0
MOD CODES USER NONE 0
MOD REM USER NONE 0
OMIT ZONE USER NONE 0
ENG PARAM USER NONE 0
ENG ZONES USER NONE 0
ENG O/PS USER NONE 0
ENG LINKS USER NONE 0
ENG SOAK USER NONE 0
ENG DIGI USER NONE 0
ENG PRINT USER NONE 0
ENG QUICK USER NONE 0
ENG DIAG USER NONE 0
ENG GROUP USER NONE 0
ENG ASSEM USER NONE 0
ENG TMRS USER NONE 0
ENG CHECK USER NONE 0
LR Line Restore LINE FAIL- Zone Tel line fail rest. ZONE 12.MD/COM 351
LINE FAIL- Module Tel line fail rest. MOD 12.MD/COM 351
LT Line Trouble LINE FAIL+ Zone Tel line fail trouble ZONE 12.MD/COM 351
LINE FAIL+ Mod Tel line fail trouble MOD 12.MD/COM 351
LX Local Prog end ENGINEER- Engineer mode exited EVENT ALWAYS TR 627
Event Codes (cont’d)