Galaxy 3 Series Programming Manual
D-5
Event Log (cont’d)
NOTE: M = Mandatory. NM = Non-Mandatory
NOTE: A plus (+) means an event has started. A negative (-) means an event has finished.
KEYPAD TEXT DESCRIPTION Trigger Event
PA DEL/SL PA Delayed Silent zone activated (opened). 1. PA/Duress M
PA DELAY PA Delayed zone activated (opened). 1. PA/Duress M
PA RESET PA Reset has occurred. 1. PA/Duress NM
PA SILENT PA Silent zone activated (opened). 1. PA/Duress M
PA UNSET PA Unset zone activated while group in unset condition. 1. PA/Duress M
PART SET Part Set of system or Group(s). 10. Setting M
PF RESET System has returned to the set status after a power failure. 20. Fault NM
PREWARN System or Group(s) in the Autoset Prewarning period. None NM
PRINT OC Print On Command. None NM
PRINT OL
Print On Line, the automatic printing of the Event Log. Not to be confused with the
printer on-line message from a printer.
None NM
+ PRT ENTRY Part Entry zone activated (opened). 2. Intruder NM
– PRT ENTRY Part Entry zone de-activated (closed).
2. Intruder
18. Zone restoral
NM
+ PRT FINAL Part Final zone activated (opened). 2. Intruder NM
– PRT FINAL Part Final zone de-activated (closed).
2. Intruder
18. Zone restoral
NM
PSU FLT+ Power Supply Unit fault
13. Elec. Status
20. Fault
M
PUSH SET Push Set (Exit Terminator) zone activated (opened). None NM
R.TIMESET Remote timeset. None NM
REARM Rearm of system has occurred. 10. Setting M
RECEN.SET Recent Set. Alarm occured within 5 minutes of set. 2. Intruder M
REM ABORT Remote connection timeout. None NM
REM CALL + Remote device connected. 14. menu access NM
REM CALL Remote device disconnected. 14. Menu access NM
REM COPY Remote Copy of site details via SIA has occurred. None NM
REM FAIL Remote failure after all retries. None NM
REM FIN Remote connection finished. None NM
REM ID Remote suite ID menu accessed. None NM
REM LOG Remote log menu accessed. None NM
REM MSG Remote message menu accessed. None NM
REM OVRWR Remote Overwrite via SIA has occurred. None M
REM RESET Remote reset menu accessed. None NM
REM TRY First remote connection attempt logged. None NM
REM WR/RD Diagnostics remote read/write None M
REMOVED Engineer has Removed a module from the system. 9. Tamper M
RF BATLOW RF Battery low
13. Elec. Status
15. Trouble
20. Fault
M
RF JAM RF signal jammed
15. Trouble
20. Fault
M
RF MEM! RF RIO Non Volatile Memory failed 9. Tamper M
RF SUPER RF Supervision failure
19. RF Supervision
20. Fault
M

Table of Contents

Other manuals for Honeywell Galaxy 3-48C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy 3-48C and is the answer not in the manual?

Honeywell Galaxy 3-48C Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy 3-48C
CategorySecurity System
LanguageEnglish

Related product manuals