1 – as level 0 plus 6 digit accounts.
2 – as level 1 but with event modifiers.
3 – as level 2 but with text descriptions.
Microtech [56.1.1.receiver.path.2.3] (PSTN, GSM)
Microtech [56.1.1.receiver.path.2.2] (GPRS, Ethernet)
Microtech [56.1.1.receiver.path.1.1] (USB)
Microtech format is a protocol that transmits detailed point identification information to a
computer that has the Alarm Monitoring software installed.
The menu structure and programming of the options is identical to the SIA format (see
above).
Contact ID [56.1.1.receiver.path.2.4] (PSTN, GSM)
Contact ID format is a protocol that transmits point identification information to an Alarm
Receiving Centre that is capable of receiving the Galaxy variant of contact ID.
SMS [56.1.1.receiver.path.2.5] (PSTN, GSM)
Use this option to generate and transmit SMS text messages in response to events that occur.
The events will be transmitted as text formatted as per a SIA event message. For plain test
SMS, use the SMS programming under the User Notification section instead.
Autotest [56.1.1.receiver.path.3]
Autotest [56.1.1.receiver.path.2] (USB only)
Use this option to automatically transmit an engineer test to the Monitoring Station at
programmed intervals, to indicate alarm transmission path integrity.
1=Start Time Enter the time the first engineer test is transmitted. Subsequent engineer
test transmissions are offset by the value assigned in the Intervals option.
2=Intervals* Sets the period between engineer test transmissions following the Start
Time. The range is 0 to 99 hours.
Notes:
1. If the Test Interval is 0 (default) the Autotest is disabled, even if a
Start Time has been assigned.
2. To disable Autotest enter 00:00 (default); no transmissions of test
signals can be sent at midnight.
3=Int. Test (Intelligent Test) Stops the transmission of an automatic test if any other
signal has already been sent during the autotest interval.
4=Account No.† By default this will be the account number programmed in the ARC
Reporting configuration. Enter an alternate account number here if
required.
* In GPRS this is labelled 1=Intervals

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Flex V3 Series and is the answer not in the manual?

Honeywell Galaxy Flex V3 Series Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy Flex V3 Series
CategorySecurity System
LanguageEnglish

Related product manuals