Communications [56] Galaxy Flex Installer Manual
144
† In GPRS this is labelled 2=Account No.
ARC Reports
The following menu items are used to program ARC, Aux 1, Aux 2, Aux 3 and DTMF event
Reports.
ARC Report [56.1.2.1]
Use this option to program the ARC alarm reporting parameters.
1=Account No This is the site identifier. Enter a unique number that can be a
maximum of six digits, although four digits is the standard.
2=Triggers See Triggers below.
3=RX Sequence Enter the sequence in which the panel attempts to report alarms to
receivers. Simply enter the number of each receiver in sequence. Each
receiver can be entered multiple times if required. Do not include
DTMF receivers in the ARC sequence.
Example:
1123 When an alarm occurs, the panel attempts to report the event
via the receiver programmed in the sequence. If that attempt fails the
panel try’s the next programmed receiver and so on until it successfully
reports the alarm or all receivers in the sequence have been attempted.
In the example above, the panel will attempt receiver 1 twice before
trying receiver 2 then receiver 3.
4=Audio Receiver Use this receiver if the alarm message is to be followed by audio
transmission for alarm verification. This prevents normal receivers
from being blocked by longer phone calls caused by the audio listen-in
process.
5=IP Check Use this option enable and disable the periodic transmission check to a
compatible monitoring station on the IP paths. This check signal is
different from an autotest signal in that the IP Check will test to make
sure there is at least one good path to the monitoring station. It does not
check the backup paths if the main path is good. However it can be set
for a more frequent poll rate if required. (0=Disabled, 1=Enabled).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Flex V3 Series and is the answer not in the manual?

Honeywell Galaxy Flex V3 Series Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy Flex V3 Series
CategorySecurity System
LanguageEnglish

Related product manuals