36-KI-16-26
Issue 3
Page 1 of 3
MagneW 3000
PLUS
Remote Converter Model Selection Guide
Instructions
Select the desired key number. The arrow to the right marks the selection available.
Make one selection from Tables I thru III, using the column below the proper arrow.
Select as many Table IV options as desired. (If no selections are desired, specify 00.)
A dot ( ) denotes unrestricted availability. A letter denotes restricted availability.
Restrictions follow Table IV.
A complete Model Number must have the designated number of digits in each table.
Key Numbe
I II III IV
_ _ _ _ _ _ - _ _ _ _ - _ _ _ _ - _ _ - _ , _
*
= Stocked
KEY NUMBER Selection Availability
Description
MagneW 3000
PLUS
Remote Converter
MGG14C
TABLE I
A - Power Suppl
AC100V 50/60Hz - Refer to Factory for Delivery A _ _ _
AC110V 50/60Hz - Refer to Factory for Delivery B _ _ _
AC115/120V 50/60Hz C _ _ _
AC200V 50/60Hz - Refer to Factory for Delivery D _ _ _
AC220V 50/60Hz - Refer to Factory for Delivery E _ _ _
AC230/240V 50/60Hz F _ _ _
f
DC24V (Noise Filter 50Hz) G _ _ _
DC24V (Noise Filter 60Hz)
H _ _ _
B - Output Signal/Communication
Volume Flow 4-20mA DC Output/without Communication (Active 4-20) _ A _ _
Volume Flow 4-20mA DC Output/with Communication (Passive 4-20) _ B _ _
Volume Flow DE Output/with Communication _ C _ _
Volume Flow Fieldbus Output/with Communication Note 1 _ F _ _
Volume Flow HART Protocol Output/with Communication
_ H _ _
C - Conduit Connection/Watertight Gland
G1/2 Internal Thread/without Watertight Gland ( Not CSA/FM approved)
_ _ 1 _
G1/2 Internal Thread/with brass (Ni-plated) Watertight Gland _ _ 2 _
(Not CSA/FM approved)
G1/2 Internal Thread/with Plastic Watertight Gland ( Not CSA/FM approved)
_ _ 3 _
1/2 NPT Internal Thread/without Watertight Gland (CSA/FM approved)
_ _ 4 _
CM20 Internal Thread/without Watertight Gland (Not CSA/FM approved)
_ _ 5 _
Pg13.5 Internal Thread/without Watertight Gland (Not CSA/FM approved)
_ _ 6 _
G1/2 Internal Thread/with SUS304 Watertight Gland (Not CSA/FM approved)
_ _ 7 _
D - Installation/Wiring Direction
Wall Mounting with Standard Bracket _ _ _ G
2B Pipe Mounting with Standard Bracket _ _ _ H
Without Mounting Bracket
_ _ _ X