EasyManua.ls Logo

Honeywell MagneW 3000 Plus - Page 57

Honeywell MagneW 3000 Plus
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36-KI-16-29
Page 2 of 3
Availability
MGG17D
TABLE I (Continued) Selection
D - Electrodes
SUS316L _ _ _ _ _ _ L _ _ _ _ _
*
Hastelloy C (with Teflon PFA only) _ _ _ _ _ _ C _ _ _ _ _ c
Titanium _ _ _ _ _ _ K _ _ _ _ _
Zirconium
(with Teflon PFA only) _ _ _ _ _ _ H _ _ _ _ _ c
Tantalum (with Teflon PFA only) _ _ _ _ _ _ T _ _ _ _ _ c
Tungsten Carbide (only for size 10mm and above) _ _ _ _ _ _ W _ _ _ _ _ e
Platinum-Iridium (with Teflon PFA only) _ _ _ _ _ _ P _ _ _ _ _ c
Alloy 20 (with Teflon PFA only) _ _ _ _ _ _ A _ _ _ _ _ c
Hastelloy B (with Teflon PFA only) _ _ _ _ _ _ B _ _ _ _ _ c
SUS304 (with Teflon PFA only) _ _ _ _ _ _ E _ _ _ _ _ c
Monel (with Teflon PFA only) _ _ _ _ _ _ M _ _ _ _ _ c
Nickel (with Teflon PFA only) _ _ _ _ _ _ N _ _ _ _ _ f
SUS316L Protruded Tip (with Teflon PFA 15-200mm only) _ _ _ _ _ _ 1 _ _ _ _ _ f
SUS316L for Alumina with Flat Tip (with Teflon PFA 15-200mm only) _ _ _ _ _ _ 2 _ _ _ _ _ f
SUS316L for Alumina with Pointed Tip (with Teflon PFA 15-200mm only)
_ _ _ _ _ _ 3 _ _ _ _ _
f
E - Grounding Rings
SUS316 _ _ _ _ _ _ _ S _ _ _ _
*
SS Top Hat Style (Upstream Only) _ _ _ _ _ _ _ G _ _ _ _ c
Hastelloy C (with Teflon PFA only) _ _ _ _ _ _ _ C _ _ _ _ c
Titanium _ _ _ _ _ _ _ K _ _ _ _
Zirconium
(with Teflon PFA only) _ _ _ _ _ _ _ H _ _ _ _ c
Tantalum (with Teflon PFA only) _ _ _ _ _ _ _ T _ _ _ _ c
Platinum (with Teflon PFA only) _ _ _ _ _ _ _ P _ _ _ _ c
Alloy 20 (with Teflon PFA only) _ _ _ _ _ _ _ A _ _ _ _ c
Hastelloy B (with Teflon PFA only) _ _ _ _ _ _ _ B _ _ _ _ c
SUS304 (with Teflon PFA only) _ _ _ _ _ _ _ E _ _ _ _ c
SUS316L (with Teflon PFA only) _ _ _ _ _ _ _ L _ _ _ _ c
Nickel (with Teflon PFA only)
_ _ _ _ _ _ _ N _ _ _ _
c
F - Wiring Connection
1/2" NPT Internal Thread without Watertight Gland
_ _ _ _ _ _ _ _ 5 _ _ _
*
G - Face to Face Dimension
Standard _ _ _ _ _ _ _ _ _ A _ _
*
Competitive (Refer to Table 103 and Consult Factory)
_ _ _ _ _ _ _ _ _ 9 _ _
H - Installation/Wiring Direction - Remote Only
Upstream Side (horizontal/vertical piping mounting) _ _ _ _ _ _ _ _ _ _ A _
*
Downstream Side (horizontal/vertical piping mounting) _ _ _ _ _ _ _ _ _ _ B _
Horizontal Piping Mounting/Left Side Viewed from Upstream _ _ _ _ _ _ _ _ _ _ C _
Horizontal Piping Mounting/Right Side Viewed from Upstream
_ _ _ _ _ _ _ _ _ _ D _
I - Calibration
Standard Calibration - 2 Point (0, 100%) w/ Master Converter _ _ _ _ _ _ _ _ _ _ _ R
*
3 Point (0, 50, 100%) with Master Converter _ _ _ _ _ _ _ _ _ _ _ P
5 Point (0, 25, 50, 75, 100%) with Master Converter _ _ _ _ _ _ _ _ _ _ _ Q
2 Point (0, 100%) with Customer’s Specific Converter _ _ _ _ _ _ _ _ _ _ _ J
3 Point (0, 50, 100%) with Customer’s Specific Converter _ _ _ _ _ _ _ _ _ _ _ A
5 Point (0, 25, 50, 75, 100%) with Customer’s Specific Converter
_ _ _ _ _ _ _ _ _ _ _ E

Table of Contents