Cable Installation (Secondary Scanner)  
The following steps describe how to properly install the cables between a secondary scanner and the MS2420.  
The MS2420 and the secondary scanner must then be configured to communicate properly. Cable installation 
alone does not guarantee that the MS2420 will communicate properly with the host system and secondary 
scanner.   
Note:   Contact a customer service representative before connecting another manufacturer’s scanner to the 
MS2420 as a secondary scanner.   
  Configuration bar codes are located in the MS2xxx Stratos Series Configuration Addendum 
(PN 00-02034x) under Scanner Configuration Bar Codes: Auxiliary Port, Quick Start for a Secondary 
Scanners. 
1.  Refer to pages 18 - 23 for the type of interface (RS232, RS485, etc.) required for the application.  Follow 
the cable installation steps under the appropriate interface before continuing.  Once the communication 
and power cables have been installed follow step 2 below for the secondary scanner installation. 
2. Connect the straight end of the RS232 PowerLink AUX cable (PN 57-57099x-3) into the RS232 socket of 
the secondary scanner (see the figure on page 26). 
3. Connect the angled end of the RS232 AUX cable (PN 57-57099x-3) into the 10-pin socket labeled  
Aux RS232 In, on the bottom of the MS2420. 
 
Note:  The MS2420 series aux port requires the signals; transmit, receive, RTS & CTS from the 
secondary scanner. 
    MS2420’s auxiliary port will support 5VDC devices with a 150mA maximum current.  If the 
auxiliar
y device exceeds this specification, an external power supply will be required to power 
the auxiliary device. 
    The following scanners can receive power from MS2420: the MS9520, MS9540, and the 
MS5145. 
4.  This step is required for secondary devices that require >5VDC and/or 150mA current to operate.  
Skip to step 5 if the secondary device requires ≤ 5VDC. 
  Plug the power supply into the secondary scanner’s PowerLink cable (PN 57-57099x-3) and connect AC 
power to the secondary scanner. 
  Note:   Check the AC input requirements of the power supply to make sure the voltage matches the AC 
outlet.  The outlet should be located near the equipment and be easily accessible. 
5.  Configure the MS2420 and the secondary scanner.  The auxiliary input port’s data format must match the 
main output format of the secondary scanner. 
  Note:   Refer to the MS2xxx Stratos Series Configuration Addendum (PN 00-02034x) under Scanner 
Configuration Bar Codes: Auxiliary Port, Quick Start for a Secondary Scanners.