Benzene Mode
The MultiRAE or MultiRAE Pro equipped with a 9.8eV lamp can perform snapshot compound-
specific (benzene) measurement in addition to general VOC measurement. This requires using
a RAE-Sep Tube Cartridge (P/N: M01-3222-000, available in packs of 6: P/N M01-0312-000)
and having the instrument in Benzene Mode. Refer to section 8 for details.
Notes:
l
When prompted to start benzene sampling, there is an option to view a tutorial. This is
helpful if you do not have this User’s Guide in the field or if you are unfamiliar with how
to ready the MultiRAE for benzene sampling. If the option is not shown, follow the
procedure on section 7.10.
l
Benzene sampling is done in a “snapshot,” meaning that the instrument does not
continuously monitor for benzene.
Honeywell MultiRAE Series™ 29 User Manual