10 www.honeywell.com
NetAXS™ NX4S1 Installation
Installation
14.Attach the negative (black) Power Supply-to-Battery cable to the negative (black) battery
terminal.
15.For panels using the Ethernet connection, the cable clamp (HAS part number 3-000342) must
be used for the panel to pass the FCC Part 15 Class B requirements. Snap the clamp around any
portion of the Ethernet cable that is inside of the enclosure.
4.1 Cabinet Mounting
The following five figures show the back, top, bottom, right, and left views of the NetAXS™ panel
cabinet. Each view includes the dimensions and knockout placement that you will need to mount the
cabinet. All dimensions are given in inches. See Table 1 on page 14 for dimensions of the conduit
entries into the cabinet.
Figure 2: NetAXS™ NX4S1 Panel Cabinet, Front View
1/4" (6.25 mm)
1 23/32" (43.75 mm) diameter knockout
3/8" (9.375 mm) diameter
(3 holes)
17 23/32" (450 mm)
12 1/16" (306.25 mm)
1/4" (6.25 mm)
Ø
0
3/4" (18.75 mm)
1 23/32" (43.75
7 1/8" (181.25 mm)
12 9/16" (318.75 mm)
13 3/4" (343.75 mm)
14 7/32" (362.50
0
2 30/32"" (75 mm)
15 3/4" (400 mm)
0
2 30/32" (75 mm)
7 1/8" (181.25 mm)
0
31/32" (25 mm)
14 9/32" (362.5 mm)