8 PW-7000 (PW7K1IC) Installation and Configuration Guide, Document 800-25673V1
Note: Total current draw for all included assemblies shall not exceed 4A, including input
rating and output load current.
Suitable for S319, Class I
Suitable for the following UL293/UL294 Performance Levels:
Endurance: IV
Standby: I
Line Security: I
Attack: I
Suitable panic or exit hardware shall be employed for fail secure applications.
For UL293 applications, the Sys Fault contacts of the power supply and the door
held, door forced shall be monitored by suitable audible device.