Power supply unit Specifications
Wattage 685 W
Rated Voltage Range 100–240 VAC
Rated Line Frequency 50–60 Hz
Rated Input Current 100-240 V @ 9.7 A
Heat dissipation (Configuration and software dependent) Maximum – 2750 btu/hr
Temperature Runs in the temperature Class/Severity A2 limits (18-27 °C) per
ANSI/ISA-S71.01-1985 Standard*
Operating 10 °C to 35 °C (50 °F to 95 °F)
Storage -40 °C to +65 °C (-40°F to 149 °F)
Relative humidity Runs in the humidity Class/Severity A2 limits (20-80%) per
ANSI/ISA-S71.01-1985 Standard*
Humidity Operating 20 % to 80 % RH, non-condensing
Maximum Altitude
Operating
15.2 m to 3,048 m (-50 ft to 10,000 ft)
Non-operating 15.2 m to 10,668 m, (-50 ft to 35,000 ft)
Airborne
contaminant level
< 300 angstroms/month Copper Reactivity Level
< 3 mm
3
/m
3
parts per billion H
2
S Gas concentration
< 10 mm
3
/m
3
parts per billion S0
2
, S0
3
Gas concentration
< 1 mm
3
/m
3
parts per billion CI
2
Gas concentration
< 50 mm
3
/m
3
parts per billion NO
X
Gas concentration
< 1 mm
3
/m
3
parts per billion HF Gas concentration
< 500 mm
3
/m
3
parts per billion NH
3
Gas concentration
< 2 mm
3
/m
3
parts per billion O
3
Gas concentration
Severity level G1 mild environment limits per ANSI/ISA-S71.04-
1985 Standard**
Maximum