Exiting the User Edit Mode
Press either [T] or [#], or don’t press any key for 10 seconds.
Bank Safe and Vault
Th e Ban k Saf e or V au l t sh oul d be l i mi t ed t o i t s ow n par t i t i on w h er e on l y a M ast er or M anager cod e w ou l d
be al l ow ed t o oper at e (see Sect i on 2 of t h i s M an u al - Partitioning). I f r egul ar u ser s ar e enabl ed t h er e i s a
w ay t o di sabl e t h ei r access (see bel ow ):
1. E n t er Sch edu l i n g M ode by en t er i n g I n st al l er Code + [ #] + [ 80] .
2. Sel ect T i m e Wi n dow s.
3. Cr eat e T i m e Wi n dow 01 as -6:00am-10:00am.
4. Cr eat e Time Window 02 as 9:30pm-10:00pm, ent er 00* to exit Time Windows.
5. D o n ot Qu i t M en u M ode, go t o O/C Sch edu l es.
6. Ent er Vault Par t it ion #.
7. Assign Window 01 as t he OP window and Window 02 as the Cl Window for Monday thru Saturday. Exit
Pr ogr am m ode.
Vault Partition
1. Pr ogram 2
05 = 00, Auto-Ar m Delay (par t i ti on-speci f i c) Ar m at 10pm.
2. Pr ogr am 2
06 = 00, Auto-Arm Warning Period (partition-sp eci fi c) N o War n i n g Per i od.
3. Pr ogram 2
07 = 00, Auto-Disarm Del ay (par t i ti on-speci fi c) Di sarm at 6am.
4. Pr ogram 2
08 = 1, F or ce A r m (partition-speci fi c) Enabl e.
5. Pr ogram 2
10 = 1, Allow Disarming Only During Arm/Disarm Windows (partition-speci fi c).
6. Pr ogram 2
11 = 0, Allow Disarm Outside Window if Alarm Occurs.
Panel wil l ar m at 10pm M onday t hru Satur day wit h no warning and Only Master /Manager can disarm
between 10pm and 6am.
To al so D i sabl e t h e M ast er /M an ager from Disarming bet ween 10pm and 6am All Master /M anager codes will
on l y w or k bet w een 6am an d 10pm M on day t h r u Sat u r day. Th ey w i l l n ot w or k on Su n day or H ol i days.
1. E n t er pr ogr am m ode I n st al l er s code + #80
2. E n t er Ti m e Wi n dow s’ and Cr eat e w i n dow 03 f or 6:00am-10:00pm, ent er 00 +
t o exi t Ti m e Wi n dow s
3. D o n ot Qu i t M en u M ode, go t o A ccess Sch ed.
4. Cr eat e Access Sched 01 by assigning Window 03 t o A1 Monday t hru Saturday. Exit Pr ogr am mode
5. A ssi gn al l M ast er and M anager Codes t o Access Sch edu l e 01 w h en u ser codes ar e assi gn ed.
Open an d Cl osed w i n d ow can be r em oved f r om sch edu l e f or Sat u r day t o pr even t r egu l ar u ser s (i f t h ey ar e
en abl ed f or t h i s par t i cu l ar par t i t i on ) f r om bei n g abl e t o d i sar m on Sat u r day, an d w i n dow can be r em ov ed
fr om L i mi t A ccess Group 1 for Satur day to pr event M aster /Manager Access on Sat urday.
1 En t er pr ogr am m ode I n st al l er s code + #80.
2. Go t o O/C Sch edu l es.
3. E n t er V au l t Par t i t i on , go t o Sat u r day and en t er 00 f or OP and CL w i n dow .
4. Go t o A ccess Sch edu l es.
5. E n t er Sch edu le 01, go t o Saturday and ent er 00 for Window A1. Exi t pr ogr am m ode.