Scheduling
Commands
Installer-Programmed Schedule Events = Installer Code + [#] + 80 (Installer or Master
Only).
Temporary Schedule Editing = User Code + [#] + 81 (Installer, Master, Manager Only).
Extend Closing Window = User Code + [#] + 82 (Installer, Master, Manager Only).
End User Output Device Programming = User Code + [#] + 83.
NOTE: Scheduling is not permitted in ULC installations.
Relay Control
Commands
Activate Relay for Current Partition = User Code + 0.
Access Control
Commands
Activate Access Relay for Current Partition = User Code + 0.
Request to Enter/Exit = User Code + [#] + 73.
Request to Enter/Exit at Access Point = User Code + [#] + 74 + Access Point Number.
Change Access Point State = User Code + [#] + 75 + Access Point + State.
Perform a Test of the VistaKey Module = Installer Code + [#] + 78.
Perform an Access Control Card Function = User Code + [#] + 79.
Master Code + # +
65
If local programming lockout is set via downloading, programming mode cannot be
entered at the keypad unless Master Code + #65 is entered, which opens up a 24hr
window to allow the installer to enter the program mode. Once the 24hrs has expired
the program mode is again locked out.