Voyager XP User Guide 51
Access Point, when the base or Access Point connects to another scanner, or when
the alarm duration expires. To activate the alarm options for the scanner or the
base and to set the alarm duration, scan the appropriate barcode below and then
set the timeout duration (from 0-3000 seconds) by scanning digits on the
Programming Chart, then scanning Save. Default = 0 sec (no alarm).
Note: If you are out of range when you scan a barcode, you will receive an error tone even if
you do not have the alarm set. You receive the error tone since the data could not be
communicated to the base or Access Point or the host.
Alarm Sound Type
You may change the alarm type for the scanner or a CCB01-010BT-V1N base by
scanning the appropriate barcode below and then scanning a digit (0-7) barcode
and the Save barcode on the Programming Chart. Default = 0.
The sounds are as follows:
Note: The Access Point does not have a
base alarm.
Base Alarm Duration
Scanner Alarm Duration
Setting Sound
0 3 long beeps, medium pitch
1 3 long beeps, high pitch
2 4 short beeps, medium pitch
3 4 short beeps, high pitch
4 single chirps, medium pitch
5 2 chirps, then 1 chirp, medium pitch
6 single chirps, high pitch
7 2 chirps, then 1 chirp, high pitch
Base Alarm Type

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Voyager 147 Series and is the answer not in the manual?

Honeywell Voyager 147 Series Specifications

General IconGeneral
BrandHoneywell
ModelVoyager 147 Series
CategoryScanner
LanguageEnglish

Related product manuals