Double click = off or on
Press and hold = data save
Auto lock circuit board
Remains locked at power failure
FAIL SECURE
Connect to CN 4
SET
2000 LINEAR DRIVE
LOCK
MON
(Yellow)
1-way day mode
setting is:
jumper or switch
from 13 to15
and 15 to 16.
16
Many other features, for autolock and motion
detector configuration, are available through
additional adjustable parameters.
These parameters can be discussed in
greater detail by calling the technical
service group.
NOTE:
2.0471d
09-07
2-way night mode
setting is:
NO
jumpers or
switches
1-way night mode
setting is:
jumper or switch from
13 to15
NO
jumper or switch from
15 to 16
15
16
15
13
13
TS 1
Security panel
connections
(optional)
CN 1
2 RED
1 BRN
4 WHT
3 GRN
5 BLK
1 2 3
5. ACTUATION FEATURES
2-way day mode
factory setting
is:
jumper or switch from
15 to16.
15
16
Com
15
13
Set jumpers or key switch for the type
of operation required.
See wiring diagram for actuation
and control switch connections
RESET
D
1
1
These displays
apply to 1.17 and
up only
UP DOWN
Display Scroll
C
N
5
C
N
4
CODE
DISPLAY
LOCK
(Orange)
If there is no response it
knows there is no lock.
R
H210.4
FAIL SAFE
The C2150 looks to see if there is a contact at the
lock port CN4 and if the yellow lock monitor LED
is on.
The control sends a pulse
to retract solenoid...
If there is no response it
knows there is no lock.
If the yellow LED is on...
Security panel
switch (optional)
Lock monitor
switch
Coil test
points
FAIL SAFE
Unlocks at power failure
LOCK
MON
LOCK
O
Y
Y
If the control gets a
response back, it
knows there is a
fail safe lock.
+100
SOLENOID
R
LOCK
MON
Y
LOCK
O
+100
R
+100
LOCK
LOCK
MON
O
LOCK
MON
Y
Press
SET
and
RESET
simultaneously, release
RESET
, wait 5 seconds,then release
SET
- version
number will displayed.
During initialization the control clears all ports and
the solenoid becomes inactive.
6. AUTOLOCK SET UP AND INITIALIZATION
The C2150 looks to see if there is a contact at the
lock port CN4 and if the yellow lock monitor LED
is off.
FAIL SECURE
The control sends a pulse
to retract the solenoid...
If the yellow LED is off...
O
LOCK
Y
LOCK
MON
If the control gets a
response back, it
knows there is a fail
secure lock.
R
SOLENOID
+100
O
LOCK
LOCK
MON
O
Y
LOCK