14
2. Timing Chart
30 or 50sec 30 or 50sec 30 or 50sec 30 or 50sec 30 or 50sec
30 or 50sec
9°C
THERMISTOR
COMPRESSOR
ON
OFF
1°C
POWER SWITCH
ON
HARVEST CYCLEFREEZE CYCLE
HARVEST CYCLE
(INITIAL)
OFF
PART NAME
FAN MOTOR
*KM-80BAJ,115BAJ,160BAJ
ON
OFF
ON
OFF
PUMP MOTOR
[
KM-80BAJ,160BAJ/BWJ] 50sec
[KM-115BAJ] 30sec
OFF
ON
OFF
CONTROLLER BOARD
RELAY: X6
(DV)
RELAY: X1
(COMP)
RELAY: X2
(HV/FM)
ON
RELAY: X3
(PM)
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
BIN CONTROL
SWITCH
ON
OFF
RELAY: X4
(WV)
ON
ON
FREEZE CYCLE
HARVEST CYCLE
(INCLUDING DRAIN)
FREEZE CYCLE
OFF
CLEANING VALVE
ON
OFF
FLOAT SWITCH
ON
BIN FULLHARVEST CYCLE
HARVEST CYCLE
Thermistor senses 9°C after more than
8 min 30 sec in harvest cycle
HARVEST CYCLE
Thermistor senses 9°C
after 6 min to 8 min 30 sec
in harvest cycle
DRAIN VALVE
HOT GAS VALVE
WATER VALVE
ON
OFF
6min
3min
6min
HARVEST CYCLE
(AFTER BIN FULL)
FREEZE CYCLE
Max 6 min
5 sec
Max 6 min Max 6 min
20 sec
Max 6 min
15 sec
20 sec
90 sec
Max 6 min
10 sec OFF, 50 sec ON 10 sec OFF, 50 sec ON 10 sec OFF, 50 sec ON
10䉝 10䉝
10䉝
10 sec OFF, 50 sec ON
10䉝
Max 6 min Max 6 min
KMͲ80,160:60sec
KMͲ115:90sec