5) Check for continuity across FS lead. With the water tank empty, FS should be
open. If open, continue to step 6. If closed, follow the steps in “II. E. 2. Float Switch
Cleaning.“ After cleaning FS, check it again. Replace if necessary.
6) Reconnect FS connector.
7) Move the control switch to the “ICE“ position. Replace the top panel and rear panel
in their correct positions, then plug in the appliance. After 1 min., the 1-min. ¿ ll cycle
should end and the initial harvest cycle should begin. If the initial harvest cycle
begins, FS is good and the check is complete. If the initial harvest cycle does not
begin, continue to step 8.
8) Move the control switch to the “OFF” position, then unplug the appliance.
9) Remove the top panel and the rear panel.
10) Disconnect the FS lead connector and
remove the lead wire from the grommet
opening.
11) Check for continuity across FS leads. With
the water tank full, FS should be closed. If
FS is closed and the icemaker will not switch
from the 1-min. ¿ ll cycle to the initial harvest
cycle, replace CB.
If FS is open, con¿ rm that the water tank is
full. If the water tank is not full, check the
water supply, water filters, and inlet water
valve. If the water tank is full, follow the steps
in “II. E. 2. Float Switch Cleaning.” After
cleaning FS, check it again. Replace if necessary.
Legend:
CB
–control board;
FS
-À oat switch
Fig. 6
Cube Guide
Silicone Hose
(Connect/disconnect
where indicated)
Storage Bin
Water Tank
OverÀ ow Pipe
(Disconnect from tank
bottom)
Grommet
Opening