115 VOLT GFCI
The Ground Fault Circuit Interrupter is a safety device that is designed to detect as little as 5 milliamps (±1mA) of
electrical current leakage to ground. Watkins Manufacturing Corporation recommends that the GFCI be tested prior
to each use to ensure it is functioning correctly. With the spa connected to the power supply, push the
TEST button.
The spa should stop operating and the GFCI power indicator will go out. Wait 30 seconds and then reset the GFCI
by pushing the
RESET button. The GFCI power indicator will turn on, restoring power to the spa. If the interrupter
does not perform in this manner, it is an indication of an electrical malfunction and the possibility of an electric
shock. Disconnect the plug from the receptacle until the fault has been identified and corrected.
NOTE: Failure to wait 30 seconds before resetting the GFCI may cause the spa’s POWER indicator (on the control
panel) to blink. If this occurs, repeat the GFCI test procedure.
CAUTION: Never use the GFCI as a means to disconnect power to the spa (always unplug it). If the GFCI is tripped while the spa is
plugged in, and a power outage occurs, when power returns the GFCI will automatically reset and power will flow to the spa.
SPEAKER OPERATION (OPTIONAL EQUIPMENT)
Your Hot Spring spa is designed to accommodate 2 pop-up speakers should you choose to add a Moonlight
™
entertainment system.
To operate the pop-up speakers:
To raise speaker, press down on top of speaker, release to allow speaker to raise unassisted.
1.
To lower speaker, press down on top of speaker until it stops, release to allow speaker to remain in lower position. 2.
Step 1
Step 2
NOTE: Make sure pop-up speakers are in the DOWN POSITION before closing the cover
Control Panel Operations