Operation
and
Reference
A
dc
voltage
may
be
applied
to
the
Amptd
Mod
input
to
control
the
HP
3325B
output
level,
or
a
pulse
may
he
used
to
gate
the
output.
Approximately
4-5V
cuts
off
the
output
signal,
while
approximately
-5V
doubles
the
output
(maximum
input
is
10
Vpp).
DC
or
pulse
inputs
should
not
exceed
±5
Vpk.
The
impedance
of
the
Amptd
Mod
input
is
10
kH
(5
Ml
when
AM
is
off).
Phase
Modulation
The
[0M]
(phase
modulation)
keys
in
the
data
group
enable
and
disable
phase
modulation
of
the
Main
Signal.
Phase
modulation
is
enabled
by
pressing
the
[0M
On]
([Shift]
[Clear])
key,
which
illuminates
the
OM
modulation
indicator.
Phase
modulation
is
disabled
by
pressing
the
[OM
Off]
([Shift]
[-])
key,
which
extinguishes
the
OM
modulation
indicator,
or
by
presetting
the
HP
3325B.
The
modulating
signal
is
applied
to
the
HP
3325B
through
the
rear-panel
Phase
Mod
In
connector.
The
phase
modulation
signal
at
the
rear-panel
Phase
Mod
Input
connector
should
not
exceed
±10
Vpk,.
The
input
impedance
is
40
kO.
The
modulation
signal
frequency
may
be
dc
to
5
kHz.
An
input
of
±5V
results
in
the
following
approximate
phase
deviation
(±170°
per
volt
for
the
sine
function):
HP
3325B
Function
Phase
Deviation
Sine
Square
Triangle
±Ramp
±850°
±425°
±42.5°
±85°
Modulation
Source
Mm
Soura*
Out
aav}
The
modulation
source
provides
a
second
independent
signal
source,
available
at
the
rear-panel
Mod
Source
Out
connector.
This
signal
may
be
used
to
modulate
the
main
signal
by
connecting
the
mod
source
out
connector
to
the
(amplitude
or
phase)
input
modulation
connector(s)
and
then
controlling
main
signal
modulation
and
the
mod
source
signal.
The
Mod
Source
output
signal
should
be
connected
to
the
Phase
or
Amplitude
Modulation
input
connector
with
a
BNC
coaxial
connector
at
the
rear
panel
There
is
no
interna!
connection.
0
o
T.
Arb
6
lOKKZ
2kHz
The
modulation
source
is
enabled
by
pressing
the
Mod
Source
sine
wave
or
square
wave
key.
The
modulation
source
is
disabled
by
pressing
the
Mod
Source
sine
wave
or
square
wave
key
adjacent
to
the
illuminated
Mod
Source
indicator
to
extinguish
that
indicator.
-
Arnold
The
Mod
Source
amplitude
is
entered
by
pressing
the
[Shift]
key
followed
by
the
[Amptd]
key.
The
Modulation
Source
indicator
to
the
left
of
the
display
illuminates
to
indicate
the
display
contains
a
modulation
source
value.
Valid
modulation
source
amplitudes
range
from
0.1
to
12
Vpp
with
O.IV
resolution.
Amplitudes
may
be
entered
in
either
Vpp
or
Vrms-
1-29

Table of Contents

Other manuals for HP 3325B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 3325B and is the answer not in the manual?

HP 3325B Specifications

General IconGeneral
BrandHP
Model3325B
CategoryPortable Generator
LanguageEnglish

Related product manuals